diff options
author | Ryan Kavanagh <rak@rak.ac> | 2024-11-09 12:27:52 -0500 |
---|---|---|
committer | Ryan Kavanagh <rak@rak.ac> | 2024-11-09 12:27:52 -0500 |
commit | b7cfaebc955d3738a7fa5a7c671e6aed4c6dab87 (patch) | |
tree | e509652ce86a8cc1a2bfcdc1167bb79f704e96bf /dot_local/lib/sway | |
parent | drop old x macro neomutt (diff) |
now that systemd starts sway, fix behaviour with env vars
Diffstat (limited to '')
-rw-r--r-- | dot_local/lib/sway/executable_assign-cgroups.py | 303 | ||||
-rw-r--r-- | dot_local/lib/sway/executable_session.sh | 137 |
2 files changed, 440 insertions, 0 deletions
diff --git a/dot_local/lib/sway/executable_assign-cgroups.py b/dot_local/lib/sway/executable_assign-cgroups.py new file mode 100644 index 0000000..509be36 --- /dev/null +++ b/dot_local/lib/sway/executable_assign-cgroups.py @@ -0,0 +1,303 @@ +#!/usr/bin/python3 +""" +Automatically assign a dedicated systemd scope to the GUI applications +launched in the same cgroup as the compositor. This could be helpful for +implementing cgroup-based resource management and would be necessary when +`systemd-oomd` is in use. + +Limitations: The script is using i3ipc window:new event to detect application +launches and would fail to detect background apps or special surfaces. +Therefore it's recommended to supplement the script with use of systemd user +services for such background apps. + +Dependencies: dbus-next, i3ipc, psutil, tenacity, python-xlib +""" +import argparse +import asyncio +import logging +import re +import socket +import struct +import sys +from functools import lru_cache +from typing import Optional + +from dbus_next import Variant +from dbus_next.aio import MessageBus +from dbus_next.errors import DBusError +from i3ipc import Event +from i3ipc.aio import Con, Connection +from psutil import Process +from tenacity import retry, retry_if_exception_type, stop_after_attempt + +if sys.version_info[:2] >= (3, 9): + from collections.abc import Callable +else: + from typing import Callable + + +LOG = logging.getLogger("assign-cgroups") +SD_BUS_NAME = "org.freedesktop.systemd1" +SD_OBJECT_PATH = "/org/freedesktop/systemd1" +SD_SLICE_FORMAT = "app-{app_id}.slice" +SD_UNIT_FORMAT = "app-{app_id}-{unique}.scope" +# Ids of known launcher applications that are not special surfaces. When the app is +# started using one of those, it should be moved to a new cgroup. +# Launcher should only be listed here if it creates cgroup of its own. +LAUNCHER_APPS = ["nwgbar", "nwgdmenu", "nwggrid", "onagre"] + +SD_UNIT_ESCAPE_RE = re.compile(r"[^\w:.\\]", re.ASCII) + + +def escape_app_id(app_id: str) -> str: + """Escape app_id for systemd APIs. + + The "unit prefix" must consist of one or more valid characters (ASCII letters, + digits, ":", "-", "_", ".", and "\"). The total length of the unit name including + the suffix must not exceed 256 characters. [systemd.unit(5)] + + We also want to escape "-" to avoid creating extra slices. + """ + + def repl(match): + return "".join([f"\\x{x:02x}" for x in match.group().encode()]) + + return SD_UNIT_ESCAPE_RE.sub(repl, app_id) + + +LAUNCHER_APP_CGROUPS = [ + SD_SLICE_FORMAT.format(app_id=escape_app_id(app)) for app in LAUNCHER_APPS +] + + +def get_cgroup(pid: int) -> Optional[str]: + """ + Get cgroup identifier for the process specified by pid. + Assumes cgroups v2 unified hierarchy. + """ + try: + with open(f"/proc/{pid}/cgroup", "r") as file: + cgroup = file.read() + return cgroup.strip().split(":")[-1] + except OSError: + LOG.exception("Error geting cgroup info") + return None + + +def get_pid_by_socket(sockpath: str) -> int: + """ + getsockopt (..., SO_PEERCRED, ...) returns the following structure + struct ucred + { + pid_t pid; /* s32: PID of sending process. */ + uid_t uid; /* u32: UID of sending process. */ + gid_t gid; /* u32: GID of sending process. */ + }; + See also: socket(7), unix(7) + """ + with socket.socket(socket.AF_UNIX, socket.SOCK_STREAM) as sock: + sock.connect(sockpath) + ucred = sock.getsockopt( + socket.SOL_SOCKET, socket.SO_PEERCRED, struct.calcsize("iII") + ) + pid, _, _ = struct.unpack("iII", ucred) + return pid + + +def create_x11_pid_getter() -> Callable[[int], int]: + """Create fallback X11 PID getter. + + Sway 1.6.1/wlroots 0.14 can use XRes to get the PID for Xwayland apps from + the server and won't ever reach that. The fallback is preserved for + compatibility with i3 and earlier versions of Sway. + """ + # pylint: disable=import-outside-toplevel + # Defer Xlib import until we really need it. + from Xlib import X + from Xlib.display import Display + + try: + # requires python-xlib >= 0.30 + from Xlib.ext import res as XRes + except ImportError: + XRes = None + + display = Display() + + def get_net_wm_pid(wid: int) -> int: + """Get PID from _NET_WM_PID property of X11 window""" + window = display.create_resource_object("window", wid) + net_wm_pid = display.get_atom("_NET_WM_PID") + pid = window.get_full_property(net_wm_pid, X.AnyPropertyType) + + if pid is None: + raise RuntimeError("Failed to get PID from _NET_WM_PID") + return int(pid.value.tolist()[0]) + + def get_xres_client_id(wid: int) -> int: + """Get PID from X server via X-Resource extension""" + res = display.res_query_client_ids( + [{"client": wid, "mask": XRes.LocalClientPIDMask}] + ) + for cid in res.ids: + if cid.spec.client > 0 and cid.spec.mask == XRes.LocalClientPIDMask: + for value in cid.value: + return value + raise RuntimeError("Failed to get PID via X-Resource extension") + + if XRes is None or display.query_extension(XRes.extname) is None: + LOG.warning( + "X-Resource extension is not supported. " + "Process identification for X11 applications will be less reliable." + ) + return get_net_wm_pid + + ver = display.res_query_version() + LOG.info( + "X-Resource version %d.%d", + ver.server_major, + ver.server_minor, + ) + if (ver.server_major, ver.server_minor) < (1, 2): + return get_net_wm_pid + + return get_xres_client_id + + +class CGroupHandler: + """Main logic: handle i3/sway IPC events and start systemd transient units.""" + + def __init__(self, bus: MessageBus, conn: Connection): + self._bus = bus + self._conn = conn + + @property + @lru_cache(maxsize=1) + def get_x11_window_pid(self) -> Optional[Callable[[int], int]]: + """On-demand initialization of X11 PID getter""" + try: + return create_x11_pid_getter() + # pylint: disable=broad-except + except Exception as exc: + LOG.warning("Failed to create X11 PID getter: %s", exc) + return None + + async def connect(self): + """asynchronous initialization code""" + # pylint: disable=attribute-defined-outside-init + introspection = await self._bus.introspect(SD_BUS_NAME, SD_OBJECT_PATH) + self._sd_proxy = self._bus.get_proxy_object( + SD_BUS_NAME, SD_OBJECT_PATH, introspection + ) + self._sd_manager = self._sd_proxy.get_interface(f"{SD_BUS_NAME}.Manager") + + self._compositor_pid = get_pid_by_socket(self._conn.socket_path) + self._compositor_cgroup = get_cgroup(self._compositor_pid) + assert self._compositor_cgroup is not None + LOG.info("compositor:%s %s", self._compositor_pid, self._compositor_cgroup) + + self._conn.on(Event.WINDOW_NEW, self._on_new_window) + return self + + def get_pid(self, con: Con) -> Optional[int]: + """Get PID from IPC response (sway), X-Resource or _NET_WM_PID (i3)""" + if isinstance(con.pid, int) and con.pid > 0: + return con.pid + + if con.window is not None and self.get_x11_window_pid is not None: + return self.get_x11_window_pid(con.window) + + return None + + def cgroup_change_needed(self, cgroup: Optional[str]) -> bool: + """Check criteria for assigning current app into an isolated cgroup""" + if cgroup is None: + return False + for launcher in LAUNCHER_APP_CGROUPS: + if launcher in cgroup: + return True + return cgroup == self._compositor_cgroup + + @retry( + reraise=True, + retry=retry_if_exception_type(DBusError), + stop=stop_after_attempt(3), + ) + async def assign_scope(self, app_id: str, proc: Process): + """ + Assign process (and all unassigned children) to the + app-{app_id}.slice/app{app_id}-{pid}.scope cgroup + """ + app_id = escape_app_id(app_id) + sd_slice = SD_SLICE_FORMAT.format(app_id=app_id) + sd_unit = SD_UNIT_FORMAT.format(app_id=app_id, unique=proc.pid) + # Collect child processes as systemd assigns a scope only to explicitly + # specified PIDs. + # There's a risk of race as the child processes may exit by the time dbus call + # reaches systemd, hence the @retry decorator is applied to the method. + pids = [proc.pid] + [ + x.pid + for x in proc.children(recursive=True) + if self.cgroup_change_needed(get_cgroup(x.pid)) + ] + + await self._sd_manager.call_start_transient_unit( + sd_unit, + "fail", + [["PIDs", Variant("au", pids)], ["Slice", Variant("s", sd_slice)]], + [], + ) + LOG.debug( + "window %s successfully assigned to cgroup %s/%s", app_id, sd_slice, sd_unit + ) + + async def _on_new_window(self, _: Connection, event: Event): + """window:new IPC event handler""" + con = event.container + app_id = con.app_id if con.app_id else con.window_class + try: + pid = self.get_pid(con) + if pid is None: + LOG.warning("Failed to get pid for %s", app_id) + return + proc = Process(pid) + cgroup = get_cgroup(proc.pid) + # some X11 apps don't set WM_CLASS. fallback to process name + if app_id is None: + app_id = proc.name() + LOG.debug("window %s(%s) cgroup %s", app_id, proc.pid, cgroup) + if self.cgroup_change_needed(cgroup): + await self.assign_scope(app_id, proc) + # pylint: disable=broad-except + except Exception as exc: + LOG.error("Failed to modify cgroup for %s: %s", app_id, exc) + + +async def main(): + """Async entrypoint""" + try: + bus = await MessageBus().connect() + conn = await Connection(auto_reconnect=False).connect() + await CGroupHandler(bus, conn).connect() + await conn.main() + except DBusError as exc: + LOG.error("DBus connection error: %s", exc) + except (ConnectionError, EOFError) as exc: + LOG.error("Sway IPC connection error: %s", exc) + + +if __name__ == "__main__": + parser = argparse.ArgumentParser( + description="Assign CGroups to apps in compositors with i3 IPC protocol support" + ) + parser.add_argument( + "-l", + "--loglevel", + choices=["critical", "error", "warning", "info", "debug"], + default="info", + dest="loglevel", + help="set logging level", + ) + args = parser.parse_args() + logging.basicConfig(level=args.loglevel.upper()) + asyncio.run(main()) diff --git a/dot_local/lib/sway/executable_session.sh b/dot_local/lib/sway/executable_session.sh new file mode 100644 index 0000000..43c4d35 --- /dev/null +++ b/dot_local/lib/sway/executable_session.sh @@ -0,0 +1,137 @@ +#!/bin/sh +# +# Address several issues with DBus activation and systemd user sessions +# +# 1. DBus-activated and systemd services do not share the environment with user +# login session. In order to make the applications that have GUI or interact +# with the compositor work as a systemd user service, certain variables must +# be propagated to the systemd and dbus. +# Possible (but not exhaustive) list of variables: +# - DISPLAY - for X11 applications that are started as user session services +# - WAYLAND_DISPLAY - similarly, this is needed for wayland-native services +# - I3SOCK/SWAYSOCK - allow services to talk with sway using i3 IPC protocol +# +# 2. `xdg-desktop-portal` requires XDG_CURRENT_DESKTOP to be set in order to +# select the right implementation for screenshot and screencast portals. +# With all the numerous ways to start sway, it's not possible to rely on the +# right value of the XDG_CURRENT_DESKTOP variable within the login session, +# therefore the script will ensure that it is always set to `sway`. +# +# 3. GUI applications started as a systemd service (or via xdg-autostart-generator) +# may rely on the XDG_SESSION_TYPE variable to select the backend. +# Ensure that it is always set to `wayland`. +# +# 4. The common way to autostart a systemd service along with the desktop +# environment is to add it to a `graphical-session.target`. However, systemd +# forbids starting the graphical session target directly and encourages use +# of an environment-specific target units. Therefore, the integration +# package here provides and uses `sway-session.target` which would bind to +# the `graphical-session.target`. +# +# 5. Stop the target and unset the variables when the compositor exits. +# +# References: +# - https://github.com/swaywm/sway/wiki#gtk-applications-take-20-seconds-to-start +# - https://github.com/emersion/xdg-desktop-portal-wlr/wiki/systemd-user-services,-pam,-and-environment-variables +# - https://www.freedesktop.org/software/systemd/man/systemd.special.html#graphical-session.target +# - https://systemd.io/DESKTOP_ENVIRONMENTS/ +# +export XDG_CURRENT_DESKTOP=sway +export XDG_SESSION_DESKTOP="${XDG_SESSION_DESKTOP:-sway}" +export XDG_SESSION_TYPE=wayland +VARIABLES="DESKTOP_SESSION XDG_CURRENT_DESKTOP XDG_SESSION_DESKTOP XDG_SESSION_TYPE" +VARIABLES="${VARIABLES} DISPLAY I3SOCK SWAYSOCK WAYLAND_DISPLAY" +VARIABLES="${VARIABLES} XCURSOR_THEME XCURSOR_SIZE" +SESSION_TARGET="sway-session.target" +SESSION_SHUTDOWN_TARGET="sway-session-shutdown.target" +WITH_CLEANUP=1 + +print_usage() { + cat <<EOH +Usage: + --help Show this help message and exit. + --add-env NAME, -E NAME + Add a variable name to the subset of environment passed + to the user session. Can be specified multiple times. + --no-cleanup Skip cleanup code at compositor exit. +EOH +} + +while [ $# -gt 0 ]; do + case "$1" in + --help) + print_usage + exit 0 ;; + # The following flag is intentionally not exposed in the usage info: + # - I don't believe that's the right or safe thing to do; + # - systemd upstream is of the same opinion and has already deprecated + # the ability to import the full environment (systemd/systemd#18137) + --all-environment) + VARIABLES="" ;; + --add-env=?*) + VARIABLES="${VARIABLES} ${1#*=}" ;; + --add-env | -E) + shift + VARIABLES="${VARIABLES} ${1}" ;; + --with-cleanup) + ;; # ignore (enabled by default) + --no-cleanup) + unset WITH_CLEANUP ;; + -*) + echo "Unexpected option: $1" 1>&2 + print_usage + exit 1 ;; + *) + break ;; + esac + shift +done + +# Check if another Sway session is already active. +# +# Ignores all other kinds of parallel or nested sessions +# (Sway on Gnome/KDE/X11/etc.), as the only way to detect these is to check +# for (WAYLAND_)?DISPLAY and that is know to be broken on Arch. +if systemctl --user -q is-active "$SESSION_TARGET"; then + echo "Another session found; refusing to overwrite the variables" + exit 1 +fi + +# DBus activation environment is independent from systemd. While most of +# dbus-activated services are already using `SystemdService` directive, some +# still don't and thus we should set the dbus environment with a separate +# command. +if hash dbus-update-activation-environment 2>/dev/null; then + # shellcheck disable=SC2086 + dbus-update-activation-environment --systemd ${VARIABLES:- --all} +fi + +# reset failed state of all user units +systemctl --user reset-failed + +# shellcheck disable=SC2086 +systemctl --user import-environment $VARIABLES +systemctl --user start "$SESSION_TARGET" + +# Optionally, wait until the compositor exits and cleanup variables and services. +if [ -z "$WITH_CLEANUP" ] || + [ -z "$SWAYSOCK" ] || + ! hash swaymsg 2>/dev/null +then + exit 0; +fi + +# declare cleanup handler and run it on script termination via kill or Ctrl-C +session_cleanup () { + # stop the session target and unset the variables + systemctl --user start --job-mode=replace-irreversibly "$SESSION_SHUTDOWN_TARGET" + if [ -n "$VARIABLES" ]; then + # shellcheck disable=SC2086 + systemctl --user unset-environment $VARIABLES + fi +} +trap session_cleanup INT TERM +# wait until the compositor exits +swaymsg -t subscribe '["shutdown"]' +# run cleanup handler on normal exit +session_cleanup |