aboutsummaryrefslogtreecommitdiff
path: root/dot_local/lib/sway
diff options
context:
space:
mode:
authorRyan Kavanagh <rak@rak.ac>2024-11-09 12:27:52 -0500
committerRyan Kavanagh <rak@rak.ac>2024-11-09 12:27:52 -0500
commitb7cfaebc955d3738a7fa5a7c671e6aed4c6dab87 (patch)
treee509652ce86a8cc1a2bfcdc1167bb79f704e96bf /dot_local/lib/sway
parentdrop old x macro neomutt (diff)
now that systemd starts sway, fix behaviour with env vars
Diffstat (limited to 'dot_local/lib/sway')
-rw-r--r--dot_local/lib/sway/executable_assign-cgroups.py303
-rw-r--r--dot_local/lib/sway/executable_session.sh137
2 files changed, 440 insertions, 0 deletions
diff --git a/dot_local/lib/sway/executable_assign-cgroups.py b/dot_local/lib/sway/executable_assign-cgroups.py
new file mode 100644
index 0000000..509be36
--- /dev/null
+++ b/dot_local/lib/sway/executable_assign-cgroups.py
@@ -0,0 +1,303 @@
+#!/usr/bin/python3
+"""
+Automatically assign a dedicated systemd scope to the GUI applications
+launched in the same cgroup as the compositor. This could be helpful for
+implementing cgroup-based resource management and would be necessary when
+`systemd-oomd` is in use.
+
+Limitations: The script is using i3ipc window:new event to detect application
+launches and would fail to detect background apps or special surfaces.
+Therefore it's recommended to supplement the script with use of systemd user
+services for such background apps.
+
+Dependencies: dbus-next, i3ipc, psutil, tenacity, python-xlib
+"""
+import argparse
+import asyncio
+import logging
+import re
+import socket
+import struct
+import sys
+from functools import lru_cache
+from typing import Optional
+
+from dbus_next import Variant
+from dbus_next.aio import MessageBus
+from dbus_next.errors import DBusError
+from i3ipc import Event
+from i3ipc.aio import Con, Connection
+from psutil import Process
+from tenacity import retry, retry_if_exception_type, stop_after_attempt
+
+if sys.version_info[:2] >= (3, 9):
+ from collections.abc import Callable
+else:
+ from typing import Callable
+
+
+LOG = logging.getLogger("assign-cgroups")
+SD_BUS_NAME = "org.freedesktop.systemd1"
+SD_OBJECT_PATH = "/org/freedesktop/systemd1"
+SD_SLICE_FORMAT = "app-{app_id}.slice"
+SD_UNIT_FORMAT = "app-{app_id}-{unique}.scope"
+# Ids of known launcher applications that are not special surfaces. When the app is
+# started using one of those, it should be moved to a new cgroup.
+# Launcher should only be listed here if it creates cgroup of its own.
+LAUNCHER_APPS = ["nwgbar", "nwgdmenu", "nwggrid", "onagre"]
+
+SD_UNIT_ESCAPE_RE = re.compile(r"[^\w:.\\]", re.ASCII)
+
+
+def escape_app_id(app_id: str) -> str:
+ """Escape app_id for systemd APIs.
+
+ The "unit prefix" must consist of one or more valid characters (ASCII letters,
+ digits, ":", "-", "_", ".", and "\"). The total length of the unit name including
+ the suffix must not exceed 256 characters. [systemd.unit(5)]
+
+ We also want to escape "-" to avoid creating extra slices.
+ """
+
+ def repl(match):
+ return "".join([f"\\x{x:02x}" for x in match.group().encode()])
+
+ return SD_UNIT_ESCAPE_RE.sub(repl, app_id)
+
+
+LAUNCHER_APP_CGROUPS = [
+ SD_SLICE_FORMAT.format(app_id=escape_app_id(app)) for app in LAUNCHER_APPS
+]
+
+
+def get_cgroup(pid: int) -> Optional[str]:
+ """
+ Get cgroup identifier for the process specified by pid.
+ Assumes cgroups v2 unified hierarchy.
+ """
+ try:
+ with open(f"/proc/{pid}/cgroup", "r") as file:
+ cgroup = file.read()
+ return cgroup.strip().split(":")[-1]
+ except OSError:
+ LOG.exception("Error geting cgroup info")
+ return None
+
+
+def get_pid_by_socket(sockpath: str) -> int:
+ """
+ getsockopt (..., SO_PEERCRED, ...) returns the following structure
+ struct ucred
+ {
+ pid_t pid; /* s32: PID of sending process. */
+ uid_t uid; /* u32: UID of sending process. */
+ gid_t gid; /* u32: GID of sending process. */
+ };
+ See also: socket(7), unix(7)
+ """
+ with socket.socket(socket.AF_UNIX, socket.SOCK_STREAM) as sock:
+ sock.connect(sockpath)
+ ucred = sock.getsockopt(
+ socket.SOL_SOCKET, socket.SO_PEERCRED, struct.calcsize("iII")
+ )
+ pid, _, _ = struct.unpack("iII", ucred)
+ return pid
+
+
+def create_x11_pid_getter() -> Callable[[int], int]:
+ """Create fallback X11 PID getter.
+
+ Sway 1.6.1/wlroots 0.14 can use XRes to get the PID for Xwayland apps from
+ the server and won't ever reach that. The fallback is preserved for
+ compatibility with i3 and earlier versions of Sway.
+ """
+ # pylint: disable=import-outside-toplevel
+ # Defer Xlib import until we really need it.
+ from Xlib import X
+ from Xlib.display import Display
+
+ try:
+ # requires python-xlib >= 0.30
+ from Xlib.ext import res as XRes
+ except ImportError:
+ XRes = None
+
+ display = Display()
+
+ def get_net_wm_pid(wid: int) -> int:
+ """Get PID from _NET_WM_PID property of X11 window"""
+ window = display.create_resource_object("window", wid)
+ net_wm_pid = display.get_atom("_NET_WM_PID")
+ pid = window.get_full_property(net_wm_pid, X.AnyPropertyType)
+
+ if pid is None:
+ raise RuntimeError("Failed to get PID from _NET_WM_PID")
+ return int(pid.value.tolist()[0])
+
+ def get_xres_client_id(wid: int) -> int:
+ """Get PID from X server via X-Resource extension"""
+ res = display.res_query_client_ids(
+ [{"client": wid, "mask": XRes.LocalClientPIDMask}]
+ )
+ for cid in res.ids:
+ if cid.spec.client > 0 and cid.spec.mask == XRes.LocalClientPIDMask:
+ for value in cid.value:
+ return value
+ raise RuntimeError("Failed to get PID via X-Resource extension")
+
+ if XRes is None or display.query_extension(XRes.extname) is None:
+ LOG.warning(
+ "X-Resource extension is not supported. "
+ "Process identification for X11 applications will be less reliable."
+ )
+ return get_net_wm_pid
+
+ ver = display.res_query_version()
+ LOG.info(
+ "X-Resource version %d.%d",
+ ver.server_major,
+ ver.server_minor,
+ )
+ if (ver.server_major, ver.server_minor) < (1, 2):
+ return get_net_wm_pid
+
+ return get_xres_client_id
+
+
+class CGroupHandler:
+ """Main logic: handle i3/sway IPC events and start systemd transient units."""
+
+ def __init__(self, bus: MessageBus, conn: Connection):
+ self._bus = bus
+ self._conn = conn
+
+ @property
+ @lru_cache(maxsize=1)
+ def get_x11_window_pid(self) -> Optional[Callable[[int], int]]:
+ """On-demand initialization of X11 PID getter"""
+ try:
+ return create_x11_pid_getter()
+ # pylint: disable=broad-except
+ except Exception as exc:
+ LOG.warning("Failed to create X11 PID getter: %s", exc)
+ return None
+
+ async def connect(self):
+ """asynchronous initialization code"""
+ # pylint: disable=attribute-defined-outside-init
+ introspection = await self._bus.introspect(SD_BUS_NAME, SD_OBJECT_PATH)
+ self._sd_proxy = self._bus.get_proxy_object(
+ SD_BUS_NAME, SD_OBJECT_PATH, introspection
+ )
+ self._sd_manager = self._sd_proxy.get_interface(f"{SD_BUS_NAME}.Manager")
+
+ self._compositor_pid = get_pid_by_socket(self._conn.socket_path)
+ self._compositor_cgroup = get_cgroup(self._compositor_pid)
+ assert self._compositor_cgroup is not None
+ LOG.info("compositor:%s %s", self._compositor_pid, self._compositor_cgroup)
+
+ self._conn.on(Event.WINDOW_NEW, self._on_new_window)
+ return self
+
+ def get_pid(self, con: Con) -> Optional[int]:
+ """Get PID from IPC response (sway), X-Resource or _NET_WM_PID (i3)"""
+ if isinstance(con.pid, int) and con.pid > 0:
+ return con.pid
+
+ if con.window is not None and self.get_x11_window_pid is not None:
+ return self.get_x11_window_pid(con.window)
+
+ return None
+
+ def cgroup_change_needed(self, cgroup: Optional[str]) -> bool:
+ """Check criteria for assigning current app into an isolated cgroup"""
+ if cgroup is None:
+ return False
+ for launcher in LAUNCHER_APP_CGROUPS:
+ if launcher in cgroup:
+ return True
+ return cgroup == self._compositor_cgroup
+
+ @retry(
+ reraise=True,
+ retry=retry_if_exception_type(DBusError),
+ stop=stop_after_attempt(3),
+ )
+ async def assign_scope(self, app_id: str, proc: Process):
+ """
+ Assign process (and all unassigned children) to the
+ app-{app_id}.slice/app{app_id}-{pid}.scope cgroup
+ """
+ app_id = escape_app_id(app_id)
+ sd_slice = SD_SLICE_FORMAT.format(app_id=app_id)
+ sd_unit = SD_UNIT_FORMAT.format(app_id=app_id, unique=proc.pid)
+ # Collect child processes as systemd assigns a scope only to explicitly
+ # specified PIDs.
+ # There's a risk of race as the child processes may exit by the time dbus call
+ # reaches systemd, hence the @retry decorator is applied to the method.
+ pids = [proc.pid] + [
+ x.pid
+ for x in proc.children(recursive=True)
+ if self.cgroup_change_needed(get_cgroup(x.pid))
+ ]
+
+ await self._sd_manager.call_start_transient_unit(
+ sd_unit,
+ "fail",
+ [["PIDs", Variant("au", pids)], ["Slice", Variant("s", sd_slice)]],
+ [],
+ )
+ LOG.debug(
+ "window %s successfully assigned to cgroup %s/%s", app_id, sd_slice, sd_unit
+ )
+
+ async def _on_new_window(self, _: Connection, event: Event):
+ """window:new IPC event handler"""
+ con = event.container
+ app_id = con.app_id if con.app_id else con.window_class
+ try:
+ pid = self.get_pid(con)
+ if pid is None:
+ LOG.warning("Failed to get pid for %s", app_id)
+ return
+ proc = Process(pid)
+ cgroup = get_cgroup(proc.pid)
+ # some X11 apps don't set WM_CLASS. fallback to process name
+ if app_id is None:
+ app_id = proc.name()
+ LOG.debug("window %s(%s) cgroup %s", app_id, proc.pid, cgroup)
+ if self.cgroup_change_needed(cgroup):
+ await self.assign_scope(app_id, proc)
+ # pylint: disable=broad-except
+ except Exception as exc:
+ LOG.error("Failed to modify cgroup for %s: %s", app_id, exc)
+
+
+async def main():
+ """Async entrypoint"""
+ try:
+ bus = await MessageBus().connect()
+ conn = await Connection(auto_reconnect=False).connect()
+ await CGroupHandler(bus, conn).connect()
+ await conn.main()
+ except DBusError as exc:
+ LOG.error("DBus connection error: %s", exc)
+ except (ConnectionError, EOFError) as exc:
+ LOG.error("Sway IPC connection error: %s", exc)
+
+
+if __name__ == "__main__":
+ parser = argparse.ArgumentParser(
+ description="Assign CGroups to apps in compositors with i3 IPC protocol support"
+ )
+ parser.add_argument(
+ "-l",
+ "--loglevel",
+ choices=["critical", "error", "warning", "info", "debug"],
+ default="info",
+ dest="loglevel",
+ help="set logging level",
+ )
+ args = parser.parse_args()
+ logging.basicConfig(level=args.loglevel.upper())
+ asyncio.run(main())
diff --git a/dot_local/lib/sway/executable_session.sh b/dot_local/lib/sway/executable_session.sh
new file mode 100644
index 0000000..43c4d35
--- /dev/null
+++ b/dot_local/lib/sway/executable_session.sh
@@ -0,0 +1,137 @@
+#!/bin/sh
+#
+# Address several issues with DBus activation and systemd user sessions
+#
+# 1. DBus-activated and systemd services do not share the environment with user
+# login session. In order to make the applications that have GUI or interact
+# with the compositor work as a systemd user service, certain variables must
+# be propagated to the systemd and dbus.
+# Possible (but not exhaustive) list of variables:
+# - DISPLAY - for X11 applications that are started as user session services
+# - WAYLAND_DISPLAY - similarly, this is needed for wayland-native services
+# - I3SOCK/SWAYSOCK - allow services to talk with sway using i3 IPC protocol
+#
+# 2. `xdg-desktop-portal` requires XDG_CURRENT_DESKTOP to be set in order to
+# select the right implementation for screenshot and screencast portals.
+# With all the numerous ways to start sway, it's not possible to rely on the
+# right value of the XDG_CURRENT_DESKTOP variable within the login session,
+# therefore the script will ensure that it is always set to `sway`.
+#
+# 3. GUI applications started as a systemd service (or via xdg-autostart-generator)
+# may rely on the XDG_SESSION_TYPE variable to select the backend.
+# Ensure that it is always set to `wayland`.
+#
+# 4. The common way to autostart a systemd service along with the desktop
+# environment is to add it to a `graphical-session.target`. However, systemd
+# forbids starting the graphical session target directly and encourages use
+# of an environment-specific target units. Therefore, the integration
+# package here provides and uses `sway-session.target` which would bind to
+# the `graphical-session.target`.
+#
+# 5. Stop the target and unset the variables when the compositor exits.
+#
+# References:
+# - https://github.com/swaywm/sway/wiki#gtk-applications-take-20-seconds-to-start
+# - https://github.com/emersion/xdg-desktop-portal-wlr/wiki/systemd-user-services,-pam,-and-environment-variables
+# - https://www.freedesktop.org/software/systemd/man/systemd.special.html#graphical-session.target
+# - https://systemd.io/DESKTOP_ENVIRONMENTS/
+#
+export XDG_CURRENT_DESKTOP=sway
+export XDG_SESSION_DESKTOP="${XDG_SESSION_DESKTOP:-sway}"
+export XDG_SESSION_TYPE=wayland
+VARIABLES="DESKTOP_SESSION XDG_CURRENT_DESKTOP XDG_SESSION_DESKTOP XDG_SESSION_TYPE"
+VARIABLES="${VARIABLES} DISPLAY I3SOCK SWAYSOCK WAYLAND_DISPLAY"
+VARIABLES="${VARIABLES} XCURSOR_THEME XCURSOR_SIZE"
+SESSION_TARGET="sway-session.target"
+SESSION_SHUTDOWN_TARGET="sway-session-shutdown.target"
+WITH_CLEANUP=1
+
+print_usage() {
+ cat <<EOH
+Usage:
+ --help Show this help message and exit.
+ --add-env NAME, -E NAME
+ Add a variable name to the subset of environment passed
+ to the user session. Can be specified multiple times.
+ --no-cleanup Skip cleanup code at compositor exit.
+EOH
+}
+
+while [ $# -gt 0 ]; do
+ case "$1" in
+ --help)
+ print_usage
+ exit 0 ;;
+ # The following flag is intentionally not exposed in the usage info:
+ # - I don't believe that's the right or safe thing to do;
+ # - systemd upstream is of the same opinion and has already deprecated
+ # the ability to import the full environment (systemd/systemd#18137)
+ --all-environment)
+ VARIABLES="" ;;
+ --add-env=?*)
+ VARIABLES="${VARIABLES} ${1#*=}" ;;
+ --add-env | -E)
+ shift
+ VARIABLES="${VARIABLES} ${1}" ;;
+ --with-cleanup)
+ ;; # ignore (enabled by default)
+ --no-cleanup)
+ unset WITH_CLEANUP ;;
+ -*)
+ echo "Unexpected option: $1" 1>&2
+ print_usage
+ exit 1 ;;
+ *)
+ break ;;
+ esac
+ shift
+done
+
+# Check if another Sway session is already active.
+#
+# Ignores all other kinds of parallel or nested sessions
+# (Sway on Gnome/KDE/X11/etc.), as the only way to detect these is to check
+# for (WAYLAND_)?DISPLAY and that is know to be broken on Arch.
+if systemctl --user -q is-active "$SESSION_TARGET"; then
+ echo "Another session found; refusing to overwrite the variables"
+ exit 1
+fi
+
+# DBus activation environment is independent from systemd. While most of
+# dbus-activated services are already using `SystemdService` directive, some
+# still don't and thus we should set the dbus environment with a separate
+# command.
+if hash dbus-update-activation-environment 2>/dev/null; then
+ # shellcheck disable=SC2086
+ dbus-update-activation-environment --systemd ${VARIABLES:- --all}
+fi
+
+# reset failed state of all user units
+systemctl --user reset-failed
+
+# shellcheck disable=SC2086
+systemctl --user import-environment $VARIABLES
+systemctl --user start "$SESSION_TARGET"
+
+# Optionally, wait until the compositor exits and cleanup variables and services.
+if [ -z "$WITH_CLEANUP" ] ||
+ [ -z "$SWAYSOCK" ] ||
+ ! hash swaymsg 2>/dev/null
+then
+ exit 0;
+fi
+
+# declare cleanup handler and run it on script termination via kill or Ctrl-C
+session_cleanup () {
+ # stop the session target and unset the variables
+ systemctl --user start --job-mode=replace-irreversibly "$SESSION_SHUTDOWN_TARGET"
+ if [ -n "$VARIABLES" ]; then
+ # shellcheck disable=SC2086
+ systemctl --user unset-environment $VARIABLES
+ fi
+}
+trap session_cleanup INT TERM
+# wait until the compositor exits
+swaymsg -t subscribe '["shutdown"]'
+# run cleanup handler on normal exit
+session_cleanup